CPC Civils Cofferdam Installation

Client:CPC Civils
Discharge Point:Surface Watercourse
Flow Rate:60m³/hr

Background

CPC Civils were carrying out the installation of a sheet piled cofferdam. During construction dirty water infiltrated the work area and required dewatering before it could be safely discharged into the environment.

The Overall Objective

CPC Civils required a treatment system to deal with slow settling solids as a result of the construction work being carried out.

Solution

Siltbuster installed a 2 stage chemical dosing system consisting of 1 MT8 chemical mix tank and 1 HB50 Lamella Clarifier with a flow rate of between 1-60m³/hr, to remove the particulates before finally being discharged further downstream.